• HVAC Duct Mount Smoke Detectors
  • HVAC Duct Mount Smoke Detectors
  • HVAC Duct Mount Smoke Detectors
  • HVAC Duct Mount Smoke Detectors
  • HVAC Duct Mount Smoke Detectors
  • HVAC Duct Mount Smoke Detectors

HVAC Duct Mount Smoke Detectors

Type: Smoke Sensor Probe
Types of Smoke Detectors: Photoelectric Smoke Style
Product Name: HVAC Duct Mount Smoke Detectors
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
HVAC Duct Mount Smoke Detectors pictures & photos
HVAC Duct Mount Smoke Detectors
US $200-300 / Piece
Min. Order: 1 Piece
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
D4240
Operating Temperature Range
minus 20 to 70 ºC
Storage Temperature Range
minus 30 to 70 ºC
Operating Humidity Range
0% to 95% non-condensing
Air Duct Velocity
100 to 4,000 FT/min (0.5 to 20.32 m/sec)
Power Supply Voltage
24VDC / 24VAC / 240VAC
Max. Standby Current
21 mA @ 24 VDC
Max. Alarm Current
65 mA @ 24 VDC
Reset Time (with RTS451)
.03 to 0.3 sec.
eset Time (by power down)
0.6 sec. max.
Power Up Time
35 sec. max.
Alarm Response Time
15 sec.
Rectangular Dimensions
About 37X13X7cm
Square Dimensions
About 20X23X7cm
Weight
About 1.5kg
Transport Package
Standard Export Cartons
Trademark
System Sensor
Origin
China
HS Code
8531901000

Product Description


HVAC Duct Mount Smoke Detectors

 

 
Product Description

The 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit operates in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing).
 
A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance.

The detector housing provides ample wiring space, a ¾-inch conduit knockout, and built-in short-circuit protection to prevent damage to sensitive components during installation. High-contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the detector may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side).
 
As many as 50 detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, enabling the fire location to be pinpointed.

An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field-selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm).
 
Product Features

* Photoelectric, integrated low-flow technology.
* Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec).
* Versatile mounting options: square or rectangular configuration.
* Plug-in sensor offers superb false alarm immunity and the latest sensor technology.
* Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing).
* Patented sampling tube installs from the front or back of the detector with no tools required.
* Increased wiring space with a newly added ¾-inch conduit knockout.
* One easy-access Test/Reset button and improved LED status.
* Patented interconnect feature for multi-fan shutdown.
* New high-contrast terminal designations.
* Built-in short-circuit protection from operator wiring errors.
* Field-selectable settings for configuring the detector.
* Two DPDT Form-C relay contacts.
* 24 VAC/DC or 240 VAC.


Detailed Images

HVAC Duct Mount Smoke Detectors
HVAC Duct Mount Smoke Detectors
HVAC Duct Mount Smoke Detectors



HVAC Duct Mount Smoke Detectors
 
 
Specifications
 
Physical Specifications
Size: 
(Rectangular Dimensions) 
(Square Dimensions)
 
14.38 in (37 cm) Length; 5 in (12.74 cm) Width; 2.5 in (6.36 cm) Depth
7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth
Weight
About 1.5kg
Operating Temperature Range
-4° to 158°F (-20° to 70°C)
Storage Temperature Range
-22° to 158°F (-30° to 70°C)
Operating Humidity Range
0% to 95% relative humidity non-condensing
Air Duct Velocity
100 to 4,000 ft/min (0.5 to 20.32 m/sec)
Electrical Ratings
Power Supply Voltage
20-29 VDC
24 VAC 50-60 Hz
240 VAC 50-60 Hz
Input Capacitance
270 µF max.
270 µF max.
N/A
Reset Voltage
3.0 VDC min. 
2.0 VAC min.
20 VAC min.
Reset Time (with RTS451)
.03 to 0.3 sec. 
.03 to 0.3 sec.
.03 to 0.3 sec.
Reset Time (by power down)
0.6 sec. max. 
0.6 sec. max.
0.6 sec. max.
Power Up Time
35 sec. max. 
35 sec. max.
35 sec. max.
Alarm Response Time
15 sec. 
15 sec. 
15 sec.
Sensitivity Test
See detector label 
See detector label
See detector label
Current Requirements: (using no accessories)
Max. Standby Current
21 mA @ 24 VDC
65 mA RMS @ 24 VAC 60 Hz
10 mA RMS @ 240 VAC 60 Hz
Max. Alarm Current
65 mA @ 24 VDC
135 mA RMS @ 24 VAC 60 Hz
18 mA RMS @ 240 VAC 60 Hz
Contact Ratings
Alarm Initiation Contacts
(SPST)
2.0 A @ 30 VDC (resistive)
Alarm Auxiliary Contacts
(DPDT)
10A@30VDC (resistive); 10A@250VAC (resistive); ½ HP@240 VAC ; ¼ HP@120 VAC
Supervisory Contacts
(SPDT)
2.0 A @ 30 VDC (resistive); 2.0 A @ 125 VAC (resistive)


Listings

HVAC Duct Mount Smoke Detectors   HVAC Duct Mount Smoke Detectors

 

 
Company Profile

ANSORL LTD is a building automatic control system and fire alarm system provider. Over the past years, We have always been dedicated to serving the diverse needs of our customers. Although we started out as a tiny engineering and manufacturing company in China and have grown into a global player in the international safety market, Ansorl continues to work hard to earn your trust and retain your confidence in our product line.

We focus on providing advanced fire alarm, fire protection system, gas extinguishing control system, residential fire alarm detectors, explosion proof fire detectors etc. Ansorl works harder to tailor our solutions to meet your needs.

Ansorl is an ISO 9001:2008 certified manufacturer with number of testing facilities. We are also planning to expand our manufacturing and testing facilities in China to ensure that our products and manufacturing practices continue to meet the highest standards.

We invite you to get to know Ansorl better. Experience the best fire alarm technology and solution. We are convinced that you will find Ansorl superior to any other detector company in China. You'll see it in our facilities, in our people, and in the products that Ansorl makes. It's our uncommon commitment to excellence and quality, and to the automation and productivity of our customers.
 
HVAC Duct Mount Smoke DetectorsHVAC Duct Mount Smoke Detectors
HVAC Duct Mount Smoke Detectors

HVAC Duct Mount Smoke Detectors

 
Contact Us
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
HVAC Duct Mount Smoke Detectors pictures & photos
HVAC Duct Mount Smoke Detectors
US $200-300 / Piece
Min. Order: 1 Piece
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Registered Capital
147802.18 USD
Plant Area
120 square meters